Compressor failure almost never happens out of the blue. A screw compressor “tells” you about a problem in advance: the temperature creeps up, it uses more oil, it no longer reaches pressure, the sound changes. Whoever notices these signs in time fixes with a small service job what would otherwise become an expensive airend or motor repair and a production stop. Below are the 7 typical failures our service engineers meet most often: what you see, what causes it, what you can check yourself and when to call service.
Safety first: before opening the compressor doors, switch off the power, lock out the breaker and make sure there is no pressure left in the system. Hot oil and a pressurised vessel can cause serious injury.
1. Overheating — the compressor trips on temperature
What you see: a temperature alarm on the controller, the compressor stops and starts again after cooling down. Normally the airend discharge temperature is 75–95 °C; on most compressors the protection trips at 105–110 °C.
Common causes: a cooler clogged with dust, low oil level, a clogged oil filter, a failed thermostatic valve, a hot and poorly ventilated room, aged or wrong oil.
What to check yourself: how clean the cooler is (from the air side), the oil level in the sight glass, room temperature and ventilation — in summer this is the most common cause (see how to protect a compressor in summer). If the cooler is clean and there is enough oil but the temperature still rises, it is the thermostatic valve or the oil, and it needs service. Oil selection and intervals — compressor oil change.
2. Oil in the network — oil consumption has gone up
What you see: oil in the line filters, in the drain water or on tools; you have to top up oil often.
Common causes: a worn or damaged separator element, a blocked oil return (scavenge) line, too much oil, the compressor running at too low a pressure (a faulty minimum pressure valve), foam from wrong or mixed oil.
What to check yourself: the oil level (overfilling is as harmful as a shortage) and the separator pressure drop, if the controller shows it. Replacing the separator and cleaning the return line is a job for service. Oil in the network ruins the dryer and filters — and in food production, the product — so do not wait.
3. Pressure not reached — not enough air
What you see: the compressor runs loaded all the time, but the network pressure is low; tools lack power.
Common causes: leaks in the network — in a poorly maintained system 20–30% of the compressor’s output often simply escapes; a clogged air filter; an intake valve that does not open fully; slipping belts; or simply demand has grown and the compressor is no longer enough.
What to check yourself: the air filter indicator; leaks — best outside working hours, when nothing is consuming air: if the compressor still loads often, the leakage is large. Also check the pipe diameter — a narrow pipe “eats” pressure (see the pipe sizing calculator).
4. Short cycling
What you see: the compressor starts and stops every few minutes, or “jumps” between load and idle; sometimes the safety valve blows.
Common causes: a receiver that is too small (or none at all), a pressure band set too narrow, network leaks, a faulty pressure sensor or switch.
Why it is dangerous: the motor has a limit on starts per hour; frequent starts wear out contactors and the motor, and the oil never warms up fully, so water collects in it. Often the right fix is a correctly sized air receiver and a properly set pressure band; with constantly changing demand — a variable-speed (VSD) compressor.
5. Will not start or trips in operation
What you see: the compressor does not start, or stops on an alarm while running; an alarm code on the controller.
Common causes: phase loss or voltage imbalance, wrong phase sequence (after electrical work), the motor overload relay, a burnt contactor, the emergency stop, a faulty sensor.
What to check yourself: write down or photograph the alarm code — it saves the service engineer diagnosis time; check the emergency stop and the incoming breaker. Restarting without finding the cause is not a good idea — especially when the overload relay has tripped. On motors and supply — electric motor 220V or 380V.
6. Noise and vibration
What you see: a new, unusual sound — humming, knocking, whistling; vibration of the housing or the pipes.
Common causes: worn bearings in the motor or airend, a damaged coupling element, loose or worn belts, loose fixings and anti-vibration mounts.
Why you should not wait: bearing wear caught in time means a bearing replacement; caught late, it means a rotor and airend repair. A new sound has appeared — call service for a vibration check. More on bearings — how to choose a bearing.
7. Water in the network
What you see: water in line filters, tools and pneumatic cylinders; in winter — frozen pipes and valves.
Common causes: a stuck or clogged automatic drain (on the compressor, receiver or filter), an air dryer that is off or faulty, or no dryer at all. Compressed air naturally contains a lot of moisture — a 7–8 bar compressor produces tens of litres of water a day.
What to check yourself: whether the drains really discharge water (with the test button), whether the dryer is on and what dew point it shows. In winter — see winter maintenance for air systems; required air quality — the ISO 8573-1 configurator.
Quick guide: symptom → cause → action
| Symptom | Most common cause | Check yourself | Call service if… |
|---|---|---|---|
| Overheating | Dirty cooler, oil, hot room | Cooler, oil level, ventilation | It overheats with a clean cooler |
| Oil in the network | Separator, return line | Oil level | Oil consumption has gone up |
| Pressure not reached | Leaks, filter, intake valve | Filter indicator, leaks | No leaks, pressure still low |
| Short cycling | Small receiver, narrow band | Pressure settings | Safety valve blows, switch/sensor |
| Will not start / trips | Phase, voltage, relay, contactor | Alarm code, breaker | The alarm repeats |
| Noise, vibration | Bearings, coupling, belts | Belt tension | A new sound — immediately |
| Water in the network | Drain, dryer | Drain test, dew point | Drain/dryer not working |
How to prevent compressor failure
Most of the failures above start for the same reason — skipped or late service. A simple routine:
- Daily: oil level, temperature and pressure on the controller, alarm history, drain operation.
- Weekly: cooler cleanliness, unusual sound or vibration, network leaks.
- On schedule: oil and oil filter, air filter, separator — at the manufacturer’s intervals, or more often depending on conditions; belts, bearings and valves checked at planned service.
Planned service is far cheaper than an emergency repair and, most importantly, the stop is planned rather than “happening”. Our service engineers maintain screw compressors of any brand, with original or compatible spare parts.
Frequently asked questions
What is the most common cause of compressor failure?
Overheating — and its cause is usually a dirty cooler, low oil or a hot, poorly ventilated room. All of these are avoided with simple maintenance.
Can I just restart the compressor after an alarm?
Once — after writing down the code, if the cause is obvious (e.g. a power cut). If the alarm repeats, or the overload relay has tripped, repeated restarts damage the motor and airend — diagnosis is needed.
How long should a screw compressor last?
With proper maintenance a screw airend runs for tens of thousands of hours. The key factors are oil and filters changed on time, clean cooling and the right size.
Which compressor brands do you service?
Screw and piston compressors of any brand — on-site diagnosis, planned service and repair.
Conclusion
The 7 typical failures of a screw compressor — overheating, oil in the network, low pressure, short cycling, electrical trips, vibration and water in the network — almost always give early warning. A five-minute daily check and planned service turn a compressor failure from an emergency into planned work.
Your compressor is showing unusual signs? Photograph the alarm code and send us the model — we will assess it and plan the service: ☎ +995 577 42 88 70 (service), [email protected]. Compressor service → · Spare parts →